V1000
V1000 is a general purpose inverter drive covering the demands of a wide field of applications including Open-Loop-Vector functionality and the usage of PM motor without feedback
Features
- High flux braking for 50% reduction of braking time
- Quick response on load and speed changes to improves machine performance.
- Online Auto-Tuning to optimise for improved motor performance at low speed
- Open Loop Vector Control for PM motor operation.
- Safe Disable Inputs for Safe Torque OFF
Normal Duty Applications
Heavy Duty Applications
Compact Vector control Drive Ratings:
- 200V:
> 1Ph: 0.1 to 2.2 kW
> 3Ph: 0.1 to 15kW - 400V:
> 3Ph: 0.2 to 15kW
200V Single Phase
V1000 Model number | PND(kW) | IND(A) | PHD(kW) | IHD(A) |
---|---|---|---|---|
CIMR-VTBA0001BAA | 0.2 | 1.2 | 0.1 | 0.8 |
CIMR-VTBA0002BAA | 0.4 | 1.9 | 0.2 | 1.6 |
CIMR-VTBA0003BAA | 0.75 | 3.3 | 0.4 | 3.0 |
CIMR-VTBA0006BAA | 1.1 | 6.0 | 0.75 | 5.0 |
CIMR-VTBA0010BAA | 2.2 | 9.6 | 1.5 | 8.0 |
CIMR-VTBA0012BAA | 3 | 12 | 2.2 | 11 |
200V Three Phase
V1000 Model number | PND(kW) | IND(A) | PHD(kW) | IHD(A) |
---|---|---|---|---|
CIMR-VT2A0001BAA | 0.2 | 1.2 | 0.1 | 0.8 |
CIMR-VT2A0002BAA | 0.4 | 1.9 | 0.2 | 1.6 |
CIMR-VT2A0004BAA | 0.75 | 3.5 | 0.4 | 3 |
CIMR-VT2A0006BAA | 1.1 | 6 | 0.75 | 5 |
CIMR-VT2A0010BAA | 2.2 | 9.6 | 1.5 | 8 |
CIMR-VT2A0012BAA | 3 | 12 | 2.2 | 11 |
CIMR-VT2A0020BAA | 5.5 | 19.6 | 3.7 | 17.5 |
CIMR-VT2A0030FAA | 7.5 | 30 | 5.5 | 25 |
CIMR-VT2A0040FAA | 11 | 40 | 7.5 | 33 |
CIMR-VT2A0056FAA | 15 | 56 | 11 | 47 |
CIMR-VT2A0069FAA | 18.5 | 69 | 15 | 60 |
400V Single Phase
V1000 Model number | PND(kW) | IND(A) | PHD(kW) | IHD(A) |
---|---|---|---|---|
CIMR-VT4A0001BAA | 0.4 | 1.2 | 0.2 | 1.2 |
CIMR-VT4A0002BAA | 0.75 | 2.1 | 0.4 | 1.8 |
CIMR-VT4A0004BAA | 1.5 | 4.1 | 0.75 | 3.4 |
CIMR-VT4A0005BAA | 2.2 | 5.4 | 1.5 | 4.8 |
CIMR-VT4A0007BAA | 3 | 6.9 | 2.2 | 5.5 |
CIMR-VT4A0009BAA | 3.7 | 8.8 | 3 | 7.2 |
CIMR-VT4A0011BAA | 5.5 | 11.1 | 3.7 | 9.2 |
CIMR-VT4A0018FAA | 7.5 | 17.5 | 5.5 | 14.8 |
CIMR-VT4A0023FAA | 11 | 23 | 7.5 | 18 |
CIMR-VT4A0031FAA | 15 | 31 | 11 | 24 |
CIMR-VT4A0038FAA | 18.5 | 38 | 15 | 31 |
Control Characteristics | |
Product | V1000 |
Type | Compact Vector Control Drive |
Rated Output Voltage (dependent on input) | Three Ph 200V Class : 200 to 240VAC Three Ph 400V Class : 380 to 480VAC Single Ph 200V Class : 200 to 240VAC |
Motor Types | Induction Motor, Permanent Magnet Motor (IPM/SPM) |
Control Methods | Open Loop Vector Control (Current Vector), V/f Control, PM Open Loop Vector Control (for SPM and IPM motors) |
Speed Control Range | 1:100 (Open Loop Vector Control), 1:20 to 40 (V/f Control), 1:10 (PM Open Loop Vector Control) |
Starting Torque | 200% / 0.5 Hz (assumes Heavy Duty rating IM of 3.7 kW or less using Open Loop Vector Control), 50% / 6 Hz (assumes PM Open Loop Vector Control) |
Frequency Range | 0 to 400Hz |
Frequency Accuracy | Digital reference: within ±0.01% of the max. output frequency (-10°C to +50°C) Analog reference: within ±0.1% of the max. output frequency (25°C±10°C) |
Frequency Setting Resolution | Main frequency reference: 0 to 10 Vdc (20 kΩ), 4 to 20 mA (250 Ω), 0 to 20 mA (250 Ω) Main speed reference : Pulse Train Input (max. 32 kHz) |
Output Frequency Resolution |
20 bit of maximum output frequency (parameter E1-04 setting) |
Torque Limit | Open Loop Vector Control allows separate settings in four quadrants |
Accel/Decel time | 0.0 to 6000.0 s (4 selectable combinations of independent acceleration and deceleration settings) |
Environmental Factors | |
Ambient Temperature | −10 to +50˚C (open chassis), −10 to +40˚C (enclosure) |
Altitude | Up to 1000 meters |
Humidity | 95 RH% or less (no condensation) |
Shock | 10 to less than 20 Hz (9.8 m/s2) max., 20 to 55 Hz (5.9 m/s2) max. |
Area of Use | Indoors |
Protection Features | |
Motor Protection | Motor overheat protection based on output current |
Momentary Overcurrent Protection |
Drive stops when output current exceeds 200% of Heavy Duty Rating |
Overload Protection | Drive stops after 60 s at 150% of rated output current (Heavy Duty Rating) |
Overvoltage Protection | 200 V class: Stops when DC bus exceeds approx. 410 V 400 V class: Stops when DC bus exceeds approx. 820 V (approx. 740 V when power supply voltage is less than 400 V) |
Undervoltage Protection | Three-phase 200 V class: Stops when DC bus falls below approx. 190 V Single-phase 200 V class: Stops when DC bus falls below approx. 160 V Three-phase 400 V class: Stops when DC bus falls below approx. 380 V (approx. 350 V when the power supply voltage is less than 400 V) |
Momentary Power Loss Ride-Thru |
Stops after approx. 15 ms (default). Parameter settings allow the drive to continue running if power loss lasts for up to approx. 2 s |
Heatsink Overheat Protection |
Thermistor |
Stall Prevention | Separate settings allowed during acceleration, and during run. Enable/disable only during deceleration. |
Ground Fault Protection | Protection by electronic circuit |
Charge LED | Charge LED remains lit until DC bus has fallen below approx. 50 V |
Standards Compliance | UL508C IEC/EN61800-3,IEC/EN61800-5-1 ISO/EN13849-1 Cat.3 PLd,IEC/EN61508 SIL2 |
Power Specifications | |
Rated input Voltage/Frequency | Three-phase AC power supply 380 to 480 V 50/60 Hz ; DC power supply: 510 to 680 V Three-phase AC power supply 200 to 240 V 50/60 Hz ; DC power supply: 270 to 340 V Single-phase AC power supply 200 to 240 V 50/60 Hz ; DC power supply: 270 to 340 V |
Allowable Voltage Fluctuation |
−15% to 10% |
Allowable Frequency Fluctuation |
±5% |
Common Specifications | |
Carrier Frequency | 2 kHz (user-set, 2 to 15 kHz possible) |
Multi Funcction Digital Inputs | 7 Digital Inputs ( NPN or PNP ) , 24VDC. |
Multi Function Digital Outputs | P1,P2 – PC Photocoupler Output (48 Vdc (or less), 50 mA (or less)) and 1 fault relay MA-MB-MC (Digital output 30 Vdc (or less), 10 mA to 1 A ,250 Vac (or less), 10 mA to 1 A) |
Multi Function Analog Inputs | 2 Multi function Analog input A1 (0 to 10 Vdc (20 kΩ) resolution: 1/1000) & A2 ( 0 to 10 Vdc (20 kΩ) resolution: 1/1000, 4 to 20 mA or 0 to 20 mA (250 Ω) resolution: 1/500) |
Multi Function Analog Output | 1 Multi function Analog outputs AM-AC (0 to 10 Vdc (2 mA or less)Resolution: 1/1000)) |
Pulse Train | 1 Pusle Train output (0.5 to 32 kHz) 1 Pulse Train input (max 32 kHz) |
Programming Interface | Serial port or USB B port in front of VFD |
Serial communication | MEMOBUS/Modbus (RTU mode) comm. RS-485, Max. 115.2 kbps |
Optional communication Protocols | MECHATROLINK-II,MECHATROLINK-III,CC-Link, DeviceNet, CompoNet, PROFIBUS-DP , CANopen , EtherCAT,EtherNet/IP, Modbus/TCP |
Additional Functions | Momentary power loss ride-thru, Speed search, Overtorque detection, Torque limit, 17-step speed (max),Accel/decel time switch, S-curve accel/decel, 3-wire sequence, Auto-tuning (rotational, stationary tuningfor resistance between lines), Dwell, Cooling fan on/off switch, Slip compensation, Torque compensation,Frequency jump, Upper/lower limits for frequency reference, DC injection braking at start and stop,Overexcitation braking, High slip braking, PID control (with sleep function), Energy saving control, MEMOBUS comm. (RS-485/422 max, 115.2 kbps), Fault restart, Application presets, DriveWorksEZ (customized function),Removable terminal block with parameter backup function. |
V1000 solar drive is used for solar pump applications
- Suitable for BLDC and PM motor
- Suitable for surface mount and submersible pump for 3 Phase 200Volts/400volts induction motor
- wide range capacity from 0.1kW to 18.5kW
- All day run stop restart mode management
- Diagnostics and self protection features.
- Protection against dry run of pump
- Simple and faster installation and commissioning.
Download
Download catalogue
Compact Vector control Drive Ratings:
- 200V:
> 1Ph: 0.1 to 2.2 kW
> 3Ph: 0.1 to 15kW - 400V:
> 3Ph: 0.2 to 15kW
V1000 Solar Technical Electrical specification | |
Pump inverter type | V/F control with derived MPPT Technology |
Dual supply ( Grid/ Solar) | Change over Available |
input DC voltage ( VOC) | 400volts DC for 200volts Class and 800volts class for 400 volts drive |
input DC voltage ( Vmp) | 280 VDC tp 310 V Dc /510 V dc to 620 V DC |
Input DC cuttent and power | As per motor capacity |
Min frequency | 0hz selectable setting range |
Max frequency | 120Hz |
Shock | 10 to less than 20 Hz (9.8m/s2) max |
output Ac voltage | 3 phase 190-240v (-15%.+10%)/380-480V/(-15%,+10%) |
Output Ac voltage | As per chart above |
Motor frequency | 0-60Hz |
Motor control technology | V/f Control |
MPPT voltage | 230V to 360 V for 200 volts
460V to 620 V for 400 volts |
Over load capacity | 120% for ND |
Under voltage | 125V DC for 200 volts Class/ 250 for 400 volts Class |
Protection | Dry run , short circuit, Open Phase in input & output side, High Voltage, Low voltage and over load , earthing, recerse polarity. |
Ambient temp | -10deg to 50 deg |
Relative humidity | Max 95% relative humanity |