Varispeed G7
The Varispeed G7 is the first general-purpose inverter in the world to feature the 3-level control method for 400V with PWM. This control technique solves the problem of micro surges, and makes it possible to use the Varispeed G7 on existing motors.It protects motor winding and bearing and lengthen motor live.
Features
- The First Product in the world which works on 3-Level Control Method
- Accurate Torque control which protects the machine from sudden load fluctuations.
- High speed search function save the recovery time during momentary Power loss.
- Low Surge voltage, Low Electrical noise,Low Acoustic noise and Leakage current is greatly reduced
- Energy Saving control performance reduces the operational cost
- LCD keypad display: 5 lines x 16 characters, backlit, 7 languages, copy function
- Support Global Field bus Networks
- Certified under UL/cUL and CE Marking as standard
Main Application
General Purpose inverter with Advance control drive Ratings:
- 3ph 200V Class : 0.4 to 110kW
- 3ph 400V Class : 0.4 to 300kW
200V Class Three phase
G7 Model Number | Pn(kW) | In(A) |
---|---|---|
CIMR-G7A20P4 | 0.4 | 3.2 |
CIMR-G7A20P7 | 0.75 | 6 |
CIMR-G7A21P5 | 1.5 | 8 |
CIMR-G7A22P2 | 2.2 | 12 |
CIMR-G7A23P7 | 3.7 | 18 |
CIMR-G7A25P5 | 5.5 | 27 |
CIMR-G7A27P5 | 7.5 | 34 |
CIMR-G7A2011 | 11 | 49 |
CIMR-G7A2015 | 15 | 66 |
CIMR-G7A2018 | 18.5 | 80 |
CIMR-G7A2022 | 22 | 96 |
CIMR-G7A2030 | 30 | 130 |
CIMR-G7A2037 | 37 | 160 |
CIMR-G7A2045 | 45 | 183 |
CIMR-G7A2055 | 55 | 224 |
CIMR-G7A2075 | 75 | 300 |
CIMR-G7A2090 | 90 | 358 |
CIMR-G7A2110 | 110 | 415 |
400V Class Three phase
G7 Model Number | Pn(kW) | In(A) |
---|---|---|
CIMR-G7A40P4 | 0.4 | 1.8 |
CIMR-G7A40P7 | 0.75 | 3.4 |
CIMR-G7A41P5 | 1.5 | 4.8 |
CIMR-G7A42P2 | 2.2 | 6.2 |
CIMR-G7A43P7 | 3.7 | 9 |
CIMR-G7A45P5 | 5.5 | 15 |
CIMR-G7A47P5 | 7.5 | 21 |
CIMR-G7A4011 | 11 | 27 |
CIMR-G7A4015 | 15 | 34 |
CIMR-G7A4018 | 18.5 | 42 |
CIMR-G7A4022 | 22 | 52 |
CIMR-G7A4030 | 30 | 65 |
CIMR-G7A4037 | 37 | 80 |
CIMR-G7A4045 | 45 | 97 |
CIMR-G7A4055 | 55 | 128 |
CIMR-G7A4075 | 75 | 165 |
CIMR-G7A4090 | 90 | 195 |
CIMR-G7A4110 | 110 | 240 |
CIMR-G7A4132 | 132 | 270 |
CIMR-G7A4160 | 160 | 302 |
CIMR-G7A4185 | 185 | 370 |
CIMR-G7A4220 | 220 | 450 |
CIMR-G7A4300 | 300 | 605 |
Control Characteristics | |
Product | Varispeed G7 |
Type | General Purpose AC drive with advanced vector control |
Rated Output Voltage (dependent on input) | Three Ph 200V Class : 200 to 240VAC Three Ph 400V Class : 380 to 480VAC |
Motor Types | Induction Motor, |
Control Methods | Sine wave PWM [Vector with PG, open loop vector 1, open loop vector 2, V/f, and V/f with PG (switched by constant setting)] |
Speed Control Range | 1:200 (open loop vector control 2), 1:1000 (vector control with PG) |
Starting Torque | 150% at 0.3 Hz (open loop vector control 2), 150% at 0 min-1 (vector control with PG)* |
Frequency Range | 0.01 Hz to 400 Hz |
Braking Transistor | Built-in braking transistor provided for AC Drives of 15 kW or less (200/400 V) |
Frequency Accuracy | Digital reference: ±0.01%, -10˚C to +40˚C ; Analog reference: ±0.1%, 25˚C ±10˚C |
Frequency Setting Resolution | Digital reference: 0.01 Hz; Analog reference: 0.03 Hz/60 Hz (11-bit + sign) |
Output Frequency Resolution |
0.001 Hz |
Torque Limit | Can be set by parameter: 4 steps available (only when vector control) |
Accel/Decel time | 0.01 to 6000.0 s (4 selectable combinations of independent acceleration and deceleration settings) |
Environmental Factors | |
Ambient Temperature | -10˚C to 45˚C (Open chassis type) |
Altitude | 1000 m max. |
Humidity | 95% RH or less (no condensation) |
Area of Use | Indoor (Protected from corrosive gasses and dust) |
Protection Features | |
Motor Protection | Protection by electronic thermal overload relay. |
Momentary Overcurrent Protection |
Drive stops when output current exceeds 200% of the rated output current. |
Overload Protection | 150% rated output current for 1 minute, 200% rated output current for 0.5 s |
Overvoltage Protection | 200 V class: Stops when the DC bus voltage is more than approximately 410 V 400 V class: Stops when the DC bus voltage is more than approximately 820 V |
Undervoltage Protection | 200 V class: Stops when the DC bus voltage decreases to less than approximately 190 V 400 V class: Stops when the DC bus voltage decreases to less than approximately 380 V |
Momentary Power Loss Ride-Thru |
Stops when power loss is longer than 15 ms. Continues operation if power loss is shorter than 2 s (depending on parameter settings). |
Heatsink Overheat Protection |
Thermistor |
Stall Prevention | Stall prevention during acceleration/deceleration and constant speed operation |
Ground Fault Protection | Protection by electronic circuit |
Charge LED | Charge LED illuminates when DC bus voltage is more than 50 V. |
Power Specifications | |
Rated input Voltage/Frequency | 400V Class: Three-phase AC power supply: 380/400/415/440/460/480 V, 50/60 Hz ,DC power supply: 510 to 680 V 200V Class : Three-phase AC power supply: 200/208/220/230/240 V, 50/60 Hz, DC power supply: 270 to 340 V |
Allowable Voltage Fluctuation |
−15% to 10% |
Allowable Frequency Fluctuation |
±5% |
Common Specifications | |
Carrier Frequency | Derating the output current enables a maximum of 15 kHz to be set.( Based on rating ) |
Multi Funcction Digital Inputs | 12 Digital Inputs ( NPN or PNP ) . |
Multi Function Digital Outputs | 1 Programmable Relay M1-M2 (AC 250 V, max. 1 A DC 30 V, max. 1 A min. load DC 5 V, 10 mA), 1 fault relay MA-MB-MC, 4 photocouplers P1,P2,P3,P4 (Open Collector Output 48 VDC 50 mA or less) |
Multi Function Analog Inputs | 3 Multi function Analog input A1(0~+10 V), A2(4~20 mA) & A3(0~+10 V) |
Multi Function Analog Output | 2 Multi function Analog outputs FM-AC & AM-AC (-10~+10 V 2 mA) |
Pulse Train | 1 Pusle Train output (0 – 32 kHz (2 kΩ)) 1 Pulse Train input (0 to 32 kHz(3 k )Hi level:3.5 to 13.2 V input) |
Serial communication | MEMOBUS/Modbus (RTU mode) comm. RS-485/422, Max. 115.2 kbps |
Optional communication Protocols | Mechatrolink, Profibus, CC-Link, Bacnet, Devicenet, Lonworks |
Programming Interface | Serial port . |
Additional Functions | Momentary power loss restart, Speed search, Overtorque detection, Torque limit, 17-step speed operation (maximum), Accel/decel time changeover, S-curve accel/decel, 3-wire sequence, Auto-tuning (rotational or stationary), DWELL, Cooling fan ON/OFF, Slip compensation, Torque compensation, Jump frequency, Frequency upper/lower limit settings, DC injection braking at start/stop, High slip braking, PID control (with sleep function), Energy-saving control, MEMOBUS communications (RS-485/422 max. 19.2 kbps), Fault retry, Constant copy, Droop control, Torque control, Speed/torque control changeover, feed forward control, Zero-servo control, etc. |